The Chicago Plumbing Code

Spread Table

The Spread is this times the Advance

To Find the degree of the fitting to use on an offset


Degree Multiplier
5⅝° The Spread is .0985 times the Advance.
11¼° The Spread is .1989 times the Advance.
22½° The Spread is .4142 times the Advance.
30° The Spread is .5774 times the Advance.
45° The Spread is equal to the Advance.
60° The Spread is 1.7321 times the Advance.
67½° The Spread is 2.4142 times the Advance.
72° The Spread is 3.078 times the Advance.