Building Sewer Pipe
	
		
			| 
				
					
						| Material | Standard |  
						| Cast-iron pipe hub & spigot b | ASTM A 74; ASTM A 888; CISPI 301 |  
						| Ductile iron pipe | AWWA C151; AWWA C115 |  
						| Concrete pipe 24" or larger | ASTM C 14; ASTM C 76; CSA A257.1; CSA CAN/CSA A 257.2 |  
						| Copper or copper-alloy tubing (Type K) | ASTM D 1785; ASTM B 88; ASTM B 251 |  
						| Polyvinyl chloride (PVC) plastic pipe (Schedule 40) | ASTM D 1785; ASTM D 2665; ASTM D 2672; CSA CAN/CSA-B 137.3 |  
						| Glass pipe a |  |  
						| Polypropylene or Polyvinylfluorodene (PVDF) a | ASTM F1412; ASTM D 4101 |  
						| High silicon content cast- iron pipe b | ASTM F 492-1985 |  
						| Extra strength vitrified clay pipe, 21" or smaller | ASTM C 4; ASTM C 700 |  | 
	
a) For acid waste underground only, on private system, not to be connected to the public sewer.
b) The use of cast-iron pipe shall be limited to construction within private property. Cast-iron pipe will not be allowed in the public way.
(Amend Coun. J. 3-27-02, p. 82090, 3)